Abstract

The Revised NIOSH Lifting Equation (RNLE) and Lifting Fatigue Failure Tool (LiFFT) manual handling risk assessment methods require measuring horizontal load moment-arms, but from different body landmarks. Since it is unclear if these different measurement methods are interchangeable the research objectives were to determine if differences exist between RNLE and LiFFT moment-arms and determine the impact of moment-arm differences on assessment method risk interpretations. Twenty subjects lifted loads from ten vertical (floor-to-mid shin, mid shin-to-knuckle, knuckle-to-shoulder, shoulder-and-above) and horizontal (close: 30cm; intermediate: 55cm; far: 75cm) zone combination locations. Moment-arms were quantified by a motion capture system by determining the horizontal distance between reflective markers placed on the third knuckle and markers placed on the hips (LiFFT method) and ankles (RNLE method). ANOVA techniques assessed moment-arm differences within each vertical zone, and risk interpretations (low-, moderate-, high-risk) were assessed using both RNLE and LiFFT moment-arms in each assessment method. RNLE moment-arms were larger than LiFFT moment-arms in the shoulder-and-above and knuckle-to-shoulder vertical zones. LiFFT moment-arms were larger than RNLE moment arms in the mid shin-to-knuckle and floor-to-mid shin vertical zones. When LiFFT moment-arms were input into RNLE and LiFFT assessment methods there was no difference in resulting risk categories. When RNLE moment-arms were input into RNLE and LiFFT methods there was no difference in resulting risk categories. For sagittally-symmetric lifting it appears RNLE and LiFFT moment-arm measurements may be used interchangeably reducing multiple measurements.

Keywords: Manual Materials Handling, Low Back Pain, Ergonomics Risk Assessment Methods, Revised NIOSH Lifting Equation, Lifting Fatigue Failure Tool

DOI: 10.54941/ahfe1008471

Cite this paper
Downloads
0
Visits
1
Download PDF

More from this volume

← A Cryptoagility-Driven Architectural Model for Post-Quantum Cryptography Migration in Edge and Access NetworksAn Institutional Federated Readiness Assessment Framework for Multidisciplinary Research Organisations →
View all articles in Human Factors in Design, Engineering, and Computing →