Experimental investigation of damping and mass parameters of an adjustable physical hand-arm model for reproducing human mechanical impedance
Abstract
Hand-arm models enable reproducible investigation of physically coupled human-machine systems. They can substitute for the human user in experimental investigations by mechanically representing the human hand-arm system. This enables the dynamic interaction between the hand-arm system and an actual machine to be studied under controlled, reproducible, and systematically variable conditions. Adjustable hand-arm models also make it possible to represent different anthropometric characteristics and force combinations. Many existing models are either nonadjustable or show deviations from mechanical impedance responses measured in humans, particularly in the frequency range from 350 to 500 Hz. The adjustable hand-arm model investigated here is implemented as a three-mass oscillator. To address the observed deviations, two studies were conducted using the adjustable hand-arm model. In the first study, the damping behavior of the three-mass oscillator was systematically investigated. In the second study, the mass parameters of the adjustable three-mass hand-arm model were systematically varied and adapted to the measured impedance responses of the human hand-arm system. Based on these investigations, an enhanced adjustable physical hand-arm model with adapted damping and mass parameters was developed to achieve closer agreement with the measured mechanical impedance of the human hand-arm system over the investigated frequency range from 10 to 500 Hz. The new hand-arm model provides an adjustable physical representation whose damping and mass parameters are specifically adapted to the measured mechanical impedance of the human hand-arm system over the frequency range from 10 to 500 Hz. The investigated parameterization therefore, represents a frequency-dependent trade-off rather than a uniform improvement over the entire frequency range.
Keywords: Human Machine Interaction, Hand-Arm-Model, Mechanical Impedance, Modeling, Industry 5.0, Dynamic Load
DOI: 10.54941/ahfe1008475
Cite this paper
More from this volume
- AI-Enhanced Live-Streamed English Language Learning: Designing and Evaluating an Intelligent Platform for Chinese Learners
- "They Will Move": Confirmation Bias, Expectation Frames, and Premature Monitoring Drop Off in COLREG Encounters
- Automation transparency communication does not improve supervisory control performance, but shapes operator trust
- The influence of neuroticism on startle and surprise response: a flight simulator study
- EEG-Based Classification of Reward, Penalty, and Movement Events Across Four Video Games of Varying Complexity
- The Effects of Task Similarity and Time Pressure on Task Performance Following Interruptions in Complex Human-Computer Interaction Systems
- Trusting the Chain, Not the Black Box: A Provenance-Based Architecture for Human-Machine Teaming in Military Autonomy
- Design of a Simplified Humanoid Robot Face: Cultural Differences and Emotional Synchronization
- From Visual Observation to Auditory Interaction: A Human-Centered Tangible Music System Based on Physical Objects
- The Impact of Scarcity-Based Dark Patterns on User Performance, Perceived Darkness, and Workload in Subscription Services
- A Behavioral Observation Tool for Diagnosing Human–AI Interaction Profiles in Engineering Design Education
- The Mediated Moon: Semantic Mediation Between Gesture and Generative Image


AHFE Open Access