Experimental investigation of damping and mass parameters of an adjustable physical hand-arm model for reproducing human mechanical impedance

Open Access
Article
Conference Proceedings
Authors: Simon Saurbier, Johannes Roggenstein, Moritz Engelmann, Lukas Bunk, Dieter Krause, Sven Matthiesen
Abstract

Hand-arm models enable reproducible investigation of physically coupled human-machine systems. They can substitute for the human user in experimental investigations by mechanically representing the human hand-arm system. This enables the dynamic interaction between the hand-arm system and an actual machine to be studied under controlled, reproducible, and systematically variable conditions. Adjustable hand-arm models also make it possible to represent different anthropometric characteristics and force combinations. Many existing models are either nonadjustable or show deviations from mechanical impedance responses measured in humans, particularly in the frequency range from 350 to 500 Hz. The adjustable hand-arm model investigated here is implemented as a three-mass oscillator. To address the observed deviations, two studies were conducted using the adjustable hand-arm model. In the first study, the damping behavior of the three-mass oscillator was systematically investigated. In the second study, the mass parameters of the adjustable three-mass hand-arm model were systematically varied and adapted to the measured impedance responses of the human hand-arm system. Based on these investigations, an enhanced adjustable physical hand-arm model with adapted damping and mass parameters was developed to achieve closer agreement with the measured mechanical impedance of the human hand-arm system over the investigated frequency range from 10 to 500 Hz. The new hand-arm model provides an adjustable physical representation whose damping and mass parameters are specifically adapted to the measured mechanical impedance of the human hand-arm system over the frequency range from 10 to 500 Hz. The investigated parameterization therefore, represents a frequency-dependent trade-off rather than a uniform improvement over the entire frequency range.

Keywords: Human Machine Interaction, Hand-Arm-Model, Mechanical Impedance, Modeling, Industry 5.0, Dynamic Load

DOI: 10.54941/ahfe1008475

Cite this paper
Downloads
0
Visits
1
Download PDF

More from this volume

← Detecting Silent Automation Reliability Degradation - A Signal Detection Theory AnalysisPredicting Ergonomic Risk and Worker Performance Using Neural Networks with EMG and Kinematic Data →
View all articles in Human Factors in Design, Engineering, and Computing →