Blast and Physiological Wearables: Hardware Testing and Voice of the Customer Analysis

Open Access
Article
Conference Proceedings
Authors: Alexis Cady, Kelly DiCristina, Robert DeMarco, Lucas Hess, Saniyah Bullock, Michael Menegus, Dominic Cheng, Florence Chua, Jose Rodriguez
Abstract

A literature review conducted in early 2026 identified various biosignals that have the potential to be affected by blast overpressure (BOP) exposure. These key physiological markers were identified as heart rate variability (HRV), electroencephalography (EEG), and electrooculography (EOG), gait, and balance, with further investigation needed into respiratory rates. For the physiological and BOP wearable systems to be utilized in tactical military scenarios, hardware reliability and end-user acceptance must be evaluated. Methodology: Two surveys were distributed in May 2026, the first End-user Voice of the Customer (VoC) survey was distributed to U.S. Army Soldiers to determine initial wearable preferences for comfort in sensor placements, willingness to wear, form factor, and data usage. The second was a Leadership VoC survey focused on how leadership would want to receive, view, and utilize the data from BOP and physiological sensors to make informed decisions. Preliminary hardware evaluation was conducted using commercial-off-the-shelf (COTS) devices such as physiological sensors, BOP wearable sensors, and Pencil Probes. An airgun was used and the previously mentioned devices were set up in various configurations to determine if the incident pressure wave creates any noise or interference with the hardware. The level of quality/reliability was also determined between the wearable sensors and the gold-standard Pencil Probe. Results and impact: The end-user survey results identified concerns of snagging and size, preferences towards a non-intrusive, lightweight sensor, a device that can be taken on/off. The leadership survey results identified a preference for a numerical Soldier readiness score that could be displayed on a computer or tablet. During bench testing the physiological device used for testing was equipped with the capability to record EKG, HRV, IBI, respiration, temperature did not experience interference or noise from exposure to the incident pressure waveform when mounted near the blast, not connected to a person. Path Forward: Future field testing will outfit soldiers with synchronized COTS devices for physiology and BOP wearable devices. A wearable survey instrument has been developed to gather data on Soldiers’ perspectives on the comfort of the wearables during their training, which will inform the results from the Voice of the Customer survey. The results from the operational tests should provide a better understanding of the effects BOP has on the readiness and performance of the operators of Army systems.

Keywords: Blast Overpressure, Wearable Sensors, Applied Ergonomics, Physiological Monitoring, User Acceptance

DOI: 10.54941/ahfe1008517

Cite this paper
Downloads
0
Visits
2
Download PDF

More from this volume

← Evaluating Occupational Heat Stress Using Wearable Physiological Monitoring: A Field Study of Environmental and Physiological Response
View all articles in Human Factors in Design, Engineering, and Computing →