Comparison of Threshold-Based and Continuous Measurement Methods for Assessing Wrist and Finger Posture During Hand-Controller Interaction

Open Access
Article
Conference Proceedings
Authors: Olivia Hosie, Mats Isaksson, John McCormick, Oren Tirosh, Chrys Hensman
Abstract

Background. Hand-controller ergonomics are important in precision-control applications, including robot-assisted surgery, but comparisons depend on how wrist and finger posture is measured. This study examined whether threshold-based and continuous measures produced similar controller ergonomic comparisons and whether wrist-only assessment represented hand postural exposure. Methods. Twelve participants completed 1-min and 5-min trials of a game using six controllers. Wrist and finger angles were recorded using a validated wearable data glove. Outcomes included mean absolute and 95th-percentile joint angles, time beyond wrist and finger reference postures, and wrist-only, finger-only and simultaneous wrist-finger exposure. Mixed-effects models included controller, trial length and their interaction, with participant as a random intercept. Associations were examined using repeated-measures correlation. Results. Controller type significantly affected all eight kinematic outcomes, χ²(5) ≥ 40.89, p< .001. Wrist threshold exposure was strongly associated with mean absolute wrist angle (rᵣₘ = .89) and moderately associated with 95th-percentile wrist angle (rᵣₘ = .67). Associations were weaker for the fingers (rᵣₘ = .63 and .38, respectively; all p < .001). Threshold exposure and mean absolute angle produced the same controller ranking for the wrist (ρ = 1.00) and a similar ranking for the fingers (ρ = .89). Across all trials, 67.6% of threshold-defined exposure occurred in the fingers without concurrent wrist exposure. Conclusion. Threshold exposure and mean absolute angle produced similar controller comparisons, particularly for the wrist. Wrist-only assessment missed substantial finger exposure. Hand-controller assessments should include wrist and finger kinematics and select outcomes according to whether the aim is to describe exposure duration, overall posture or peak posture.

Keywords: Wearable Sensors, Hand Controllers, Wrist Posture, Finger Posture, Ergonomic Exposure

DOI: 10.54941/ahfe1008267

Cite this paper
Downloads
0
Visits
1
Download PDF

More from this volume

← Flying While Coordinating: A Work Domain Analysis of Goggles-Only FPV Pilots as Nodes in a Scalable Strike ElementPurported and Measured Waveform Characteristics of Vagus Nerve Stimulation Devices →
View all articles in Human Factors in Design, Engineering, and Computing →